Metadata

Field Value

Standardized Instrument Name

METEOROLOGICAL STATIONS

Scheme URI

http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/

Term URI

SDN:P19::PLSR0226

Instrument DOI

Instrument Unique ID

300534061454190

ID Type

Serial Number

Model No.

H22-E14, SOH118303

Instrument Type

Baseline

Description

Made up of multiple components listed below. Serial number is Iridium Weather station IMEI Equipment cost: $9,904.50 + Iridium satellite Premium Plan: $1,350 Sensor details found in attachment - Instrument Details - HOBO MMF Weather Station 2

Manufacturer

Hoskin Scientific Limited

Manufacturer type

Organizational

Notes

HOBO brand field gear that includes various sensors attached to tripod outfitted with solar panel and battery located in housing box. This meteorological station is located in Dawson Bay and is owned by the Manitoba Metic Federation (MMF). Calibration certificates stored in Lab Collector. They can be provided upon request.

Sensor Details

Sensor Details 1

Instrument Sensor Name

Temperature and Relative Humidity

Instrument Sensor Serial No.

21048242

Sensor Range

Temperature: -40°C to 75°C (-40°F to 167°F); RH: 0-100% RH at -40° to 75°C (-40° to 167°F); exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1%

Sensor Sensitivity

Temperature: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F); RH: ±2.5% from 10% to 90% RH typical to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical

Sensor Units

°C and %

Last Calibration Date

Sensor Details 2

Instrument Sensor Name

Photosynthetically Active Radiation (PAR)

Instrument Sensor Serial No.

21040572

Sensor Range

0 to 2500 μmol/m2/sec, wavelengths 400 to 700 nm

Sensor Sensitivity

±5 μmol/m2/sec or ± 5%, whichever is greater in sunlight; additional temperature induced error ±0.75 μmol/m2/sec/°C from 25°C (0.42 μmol/m2/sec/°F from 77°F)

Sensor Units

μmol/m2/sec

Last Calibration Date

Sensor Details 3

Instrument Sensor Name

Barometric Pressure

Instrument Sensor Serial No.

20812844

Sensor Range

Rated for -40C to +70C, must be used inside logger case, w/ 10 cm cable

Sensor Sensitivity

±3.0 mbar (0.088 in. Hg) over full pressure range at 25°C (77°F); maximum error of ±5.0 mbar (0.148 in. Hg) over -40° to 70°C (-40° to 158°F)

Sensor Units

mbar

Last Calibration Date

Sensor Details 4

Instrument Sensor Name

Wind sensor/monitor

Instrument Sensor Serial No.

21055170

Sensor Range

S-WCB-M003: 0 to 50 m/s (0 to 112 mph)

Sensor Sensitivity

0.20 m/s (0.46 mph) and 1.4 degrees

Sensor Units

m/s and degrees

Last Calibration Date

Sensor Details 5

Instrument Sensor Name

Rain Gauge

Instrument Sensor Serial No.

21050258

Sensor Range

0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 tips per logging interval

Sensor Sensitivity

0.01 in. (S-RGA-M002) or 0.2 mm (S-RGB-M002)

Sensor Units

mm

Last Calibration Date

Related Datasets

Field Value

Title

Dawson Bay Li Taan Aen Staansyoon

URL

https://lwbin-dev.ad.umanitoba.ca/data/dataset/mmf-2-data